MUTOH Rockhopper II Series Especificações Página 193

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 192
Rockhopper II series printers – Maintenance Manual
194
AP-74065, Rev. 1.2, 27/09/04
5.9.9. General Endurance Menu
This menu performs the general endurance running.
You can operate various driving systems according to your desired settings.
The available settings are shown below.
Setup item Description Parameters Remarks
Operation speed (CW,
CCW)
Sets carriage operation speed (CW
and CCW).
240/300 Unit: cps
Media feed amount Set the media feed amount per cycle 0 to 100 Unit: mm
Number of endurance
running cycles
Set the number of endurance running
cycles
-1 to 10000
Notes :
¾ If the number of endurance running cycles is set to -1, the units continuously repeat
endurance running until a key input is given from the operation panel.
¾ The maximum counter value for endurance running cycles is 99999999 (up to 8-digit
number). If the number of cycles exceeds the maximum value, the counter is reset to 0.
* Speed CW *
Speed 240 / 300 + Speed (CW)
240 cps -
ENTER
* Speed CCW *
Speed 240 / 300 + Speed (CCW)
240 cps -
ENTER
* Feed Amount *
0 – 100.0 mm + Media feed amount
0.1 mm -
ENTER
* Life Count *
Count
-1 10000 +
Number of total endurance running cycles
50 -
ENTER
* Total Life *
Count 5 Perform endurance running
ENTER or CANCEL
* Total Life *
End 50
Vista de página 192
1 2 ... 188 189 190 191 192 193 194 195 196 197 198 ... 318 319

Comentários a estes Manuais

Sem comentários