MUTOH Rockhopper II Series Especificações Página 235

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 234
Rockhopper II series printers – Maintenance Manual
236
AP-74065, Rev. 1.2, 27/09/04
7.13. MEDIA SENSOR SENSITIVITY ADJUSTMENT
This section explains the procedure for adjusting the sensitivity of the media sensor.
When replacing the P_EDGE sensor assembly or Mainboard assembly, adjust the media sensor.
Notes :
¾ Pay attention to the following points when adjusting the media sensor.
This should be performed in an area where sun light and illumination do not
influence the sensor.
The front cover and Y rail cover should be installed when performing the
work.
When making adjustments, hold the media by hand or the media hold lever
so that the media stays still on the sensor.
¾ If the media is lifted off, the accuracy of the sensor may be affected.
A non-conductive type screw driver should be used when adjusting the
control on the Mainboard assembly.
¾ Otherwise, a short circuit may result if the driver contacts the metal parts, such as
electronics parts on the Mainboard assembly or the frame.
7.13.1. Tools required for work
The following tools are required for adjusting the P_EDGE sensor.
Reference media: Double coated media (recommended media)
Notes :
¾ Refer to “Jig and Tool List".
7.13.2. Adjustment Procedure
Perform the adjustment following the procedures below.
Notes :
¾ The adjustment values are displayed by a decimal number from the firmware
version 1.08 onwards. Perform the adjustment after checking if the right firmware
version has been installed.
Notes :
¾ The adjustment values are as follows.
HIGH level (with media) A/D value
In hexadecimal number : D8 to DF (H)
In decimal number : 216 to 223 (H)
LOW level (without media) A/D value
In hexadecimal number : 30 to 0 (H)
In decimal number : 48 to 0 (H)
Vista de página 234
1 2 ... 230 231 232 233 234 235 236 237 238 239 240 ... 318 319

Comentários a estes Manuais

Sem comentários